EasyManuals Logo

Korg microSAMPLER User Manual

Korg microSAMPLER
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Global parameters
39
PTRN CHG (Pattern change mode) .......................... [PTRN END, BAR LINE]
This specifies the timing when the selected pattern will begin when you
switch patterns while the pattern sequencer is playing.
PTRN.END
The newly selected pattern will start when the pattern that’s currently
playing has played to its end.
BAR LINE
The newly selected pattern will start when the pattern that’s playing
reaches the end of its current measure.
AUDIO IN LVL (Audio In Level) ................................. [+0 dB, +6 dB, +12 dB]
This specifies the output volume of the audio input signal when you play
the right-most key in Sample mode (p.18 “Listening to the sound from the
AUDIO IN jacks”).
This setting does not affect the volume of the input sound that you hear
automatically when in sample-ready mode (p. 18 “3. Recording a sample”).
GLOBAL.CH (Global MIDI Channel) ...................................................[1...16]
This specifies the MIDI channel used for Sample mode and for controlling
the pattern sequencer.
KB.MIDI.CH (Keyboard MIDI Channel) ..............................................[1...16]
This specifies the MIDI channel that MIDI messages such as note-on/off are
received when in Keyboard mode.
LOCAL (MIDI Local Control) .......................................................... [OFF, ON]
This turns Local Control on/off.
OFF
The microSAMPLER’s keyboard and controllers will be disconnected
from its sound generator section.
When the microSAMPLER is connected to an external sequencer, this
setting prevents the double triggering that would otherwise occur due to
echo-back from your sequencer (performance data that is played on the
microSAMPLER’s keyboard and then re-transmitted from the sequencer
back to the microSAMPLER).
ON
Choose this setting when using the microSAMPLER by itself.
MIDI.ROUT (MIDI Routing) ......................................[USB+MIDI, USB, MIDI]
This selects the connector(s) used to transmit and receive MIDI messages.
USB+MIDI
The MIDI connectors and USB connector will be used to transmit and
receive MIDI messages. For reception, the MIDI messages from both
MIDI and USB connectors are mixed, and the MIDI messages that were
received later will be given priority. For transmission, the same MIDI
messages will be transmitted from both MIDI and USB connectors.
Select pattern 2 at this point
Pattern playback
Measure
Pattern 1
Pattern 2
Select pattern 2 at this point
Pattern playback
Measure
Pattern 1
Pattern 2
MIDI OUT
MIDI IN
TG OUTPUT
etc...
KBD/KNOB OUT
etc...
USB MIDI RX (EXT)
USB MIDI TX (INT)
USB MIDI TX (EXT)
USB MIDI RX (INT)
PC USB-MIDI Port
microSAMPLER
microSAMPLER MIDI OUT
microSAMPLER KBD/KNOB
microSAMPLER MIDI IN
microSAMPLER SOUND
Global parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Korg microSAMPLER and is the answer not in the manual?

Korg microSAMPLER Specifications

General IconGeneral
Sampling Frequency48 kHz
A/D Conversion24-bit
D/A Conversion24-bit
TypeSampler Keyboard
Keyboard37 keys (velocity sensitive)
Number of Samples36 per bank
Sequencer16, 000 notes
Display16 character x 2 line LCD
OutputsL/Mono, R (1/4" Phone), Headphones (1/4" Stereo Phone)
USBUSB MIDI
Power SupplyAC adapter (included)
InputsAudio Input (1/4" Phone), Mic Input (1/8" Phone)

Related product manuals