EasyManuals Logo

Korg microSAMPLER User Manual

Korg microSAMPLER
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
microSAMPLER
46
By sending the following NRPN messages to the microSAMPLER you can
make various settings for the pattern sequencer or the sampler. These mes-
sages are received on the global MIDI channel. The table below shows how
the parameter values of the message correspond to the microSAMPLER’s
actual parameter values.
• [PATTERN] dial: [Bn, 63, 20, Bn, 62, 01, Bn, 06, mm]
• [REC] button: [Bn, 63, 20, Bn, 62, 02, Bn, 06, mm]
• [SAMPLING] button: [Bn, 63, 20, Bn, 62, 11, Bn, 06, mm]
• [INPUT SELECT] button: [Bn, 63, 20, Bn, 62, 12, Bn, 06, mm]
microSAMPLER format
F0: Exclusive status
42: Korg ID
3n: [n=0–F] MIDI channel
7F: microSAMPLER model ID
nn: Function ID (type of message)
F7: End of exclusive
Universal system exclusive
Some system exclusive messages have officially defined uses. These are
called “universal system exclusive messages.”
Of these universal system exclusive messages, the microSAMPLER is able to
receive the Master Volume message.
Master volume [F0, 7F, nn, 04, 1, vv, mm, F7]
(vv: lower byte of value, mm: upper byte of value. Volume is at maximum
when ‘mm’ and ‘vv’ are both 7F. Volume is zero when ‘mm’ and ‘vv’ are
both 00.)
When a Master Volume message is received, the microSAMPLER’s overall
volume will be adjusted.
Synchronizing the pattern sequencer
If you want to synchronize the microSAMPLER’s pattern sequencer to a
connected external MIDI device, use the system realtime messages Start and
Stop to control the pattern sequencer.
Start [FA]
If a Start [FA] message is received when the pattern sequencer is stopped,
the pattern sequencer will start playing.
If a Start [FA] message is received during playback, the pattern sequencer
will reset to the beginning of the pattern.
Stop [FC]
If a Stop [FC] message is received, the pattern sequencer will stop.
MSB (Hex) LSB (Hex) Value (received)
[PATTERN] dial 32 (20) 01 (01)
0...7: 1, 8...15: 2, 16...23: 3, 24...31: 4,
32...39: 5, 40...47: 6, 48...55: 7, 56...63: 8,
64...71: 9, 72...79: 10, 80...87: 11,
88...95: 12, 96...103: 13, 104...111: 14,
112...119: 15, 120...127: 16
[REC] button 32 (20) 02 (02)
127: SETUP/REC STANDBY,
REC/REC END
[SAMPLING]
button
32 (20) 17 (11)
127: SETUP/SAMPLING STANDBY, SAM-
PLING/SAMPLING END
[INPUT SELECT]
button
32 (20) 18 (12) 0...63: AUDIO IN, 64...127: RE-SAMPLE
System exclusive messages
Realtime messages

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Korg microSAMPLER and is the answer not in the manual?

Korg microSAMPLER Specifications

General IconGeneral
Sampling Frequency48 kHz
A/D Conversion24-bit
D/A Conversion24-bit
TypeSampler Keyboard
Keyboard37 keys (velocity sensitive)
Number of Samples36 per bank
Sequencer16, 000 notes
Display16 character x 2 line LCD
OutputsL/Mono, R (1/4" Phone), Headphones (1/4" Stereo Phone)
USBUSB MIDI
Power SupplyAC adapter (included)
InputsAudio Input (1/4" Phone), Mic Input (1/8" Phone)