BA 35203_04 * 3.0 * 35203_04_05_Bedienung.fm 5-53
Operation 5
Operation of the additional control circuit – SKID STEER attachments (option)
Using the additional control circuit in continuous operation
The additional control circuit is used for the operation of hydraulic
attachments, for example a sweeper or a snow blower with an additional
"swiveling ejector" function.
Information
For safety reasons, the diesel engine cannot be started again (after it has
been stopped) if continuous operation is switched on (start interlock)!
Before restarting the diesel engine, switch off continuous operation of
the auxiliary control circuit.
Information
Operation of auxiliary functions, for example electro-hydraulic control
valves in the attachments, is possible with the front plug receptacle
see “7-pole front socket (option)” on page 5-54.
Fig. 154
E
D
A
B
91
9089
F
V
4
Putting the additional control circuit (115 l/min or 30.38 gal/min)
into continuous operation
1. Connect the flexible lines of the
attachment to the plug couplings D+E.
2. Slide the lock in switch 89 downward
and press the switch to position A.
3. Slide the lock in switch 90 downward
and press the switch to position B.
4. Slide the lock in switch 91 downward
and press the switch to position B.
Control display F/4
appears.
Pressure is applied to
coupling connection E.
Coupling connection D
for return.
Putting the additional control circuit out of operation
1. Press the toggle switch 91 into
position A.
2. Press the toggle switch 90 into
position A.
3. Disable the 3rd control circuit. To do
this, slide the toggle switch 89
downward and press into position A
Flat connector
plugs D+E are out of
operation.