5 Operation
14-pole front socket (option)
Important information about putting the machine into operation
Three electrical circuits for activating electro-hydraulic control valves, and
an additional electrical circuit for switching electrical functions on or off
can be operated with the 14-pole front plug receptacle A.
In order to avoid faulty operation and/or damage to the attachment, before
taking the attachment into service, the assignment of the individual circuits
in the electric plug connection of the attachment must be checked for the
assignment and operation of the 7-pole plug receptacle.
► Have troubleshooting only performed by an authorized service center.
► The assignment of the circuits (pin) in the 14-pole plug receptacle are
listed in the wiring diagram (see system manual of the vehicle).
The first 3 electrical circuits can only be operated separately. The circuit is
then shown in the digital display through the corresponding symbol
P1,2or 3.
The 4th electrical circuit symbol P/4 can be operated in addition to the
other three electrical circuits.