EasyManua.ls Logo

Kramer KIT-400

Kramer KIT-400
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
KIT-400 Protocol 3000
75
Protocol 3000
Understanding Protocol 3000 on page 75.
Protocol 3000 Commands on page 76.
Result and Error Codes on page 92.
Kramer devices can be operated using Kramer Protocol 3000 commands sent via serial or
Ethernet ports.
Understanding Protocol 3000
Protocol 3000 commands are a sequence of ASCII letters, structured according to the
following.
Command format:
Prefix
Command Name
Constant (Space)
Parameter(s)
Suffix
#
Command
Parameter
<CR>
Feedback format:
Prefix
Device ID
Constant
Command Name
Parameter(s)
Suffix
~
nn
@
Command
Parameter
<CR><LF>
Command parameters Multiple parameters must be separated by a comma (,). In
addition, multiple parameters can be grouped as a single parameter using brackets
([ and ]).
Command chain separator character Multiple commands can be chained in the
same string. Each command is delimited by a pipe character (|).
Parameters attributes Parameters may contain multiple attributes. Attributes are
indicated with pointy brackets (<…>) and must be separated by a period (.).
The command framing varies according to how you interface with KIT-400. The following
figure displays how the # command is framed using terminal communication software (such
as Hercules):