Kramer Electronics Ltd.
KIT-400 Protocol 3000
85
Function
Description
Syntax
Parameters/Attributes
Example
VMUTE
Set enable/disable
video on output.
Video mute
parameter 2 (blank
picture) is not
supported.
COMMAND
#VMUTEout_index,flag<CR>
FEEDBACK
~nn@VMUTEout_index,flag<CR><LF>
out_index Number that
indicates the specific output:
1-N (N= the total number of outputs)
flag Video Mute
0 Video disabled
1 Video enabled
2 Blank picture
Disable the video output on
OUT 2:
#VMUTE2,0<CR>
VMUTE?
Get video on output
status.
Video mute
parameter 2 (blank
picture) is not
supported.
COMMAND
#VMUTE?out_index<CR>
FEEDBACK
~nn@VMUTEout_index,flag<CR><LF>
out_index Number that
indicates the specific output:
1 HDBT OUT
flag Video Mute
0 Video disabled
1 Video enabled
2 Blank picture
Get video on output status:
#VMUTE?2<CR>
KIT-400R Protocol Commands
Function
Description
Syntax
Parameters/Attributes
Example
#
Protocol handshaking.
Validates the
Protocol 3000
connection and gets the
machine number.
Step-in master products
use this command to
identify the availability
of a device.
COMMAND
#<CR>
FEEDBACK
~nn@ok<CR><LF>
#<CR>
AUD-LVL
Set volume level.
COMMAND
#AUD-LVLio_mode,io_index,vol_level<CR>
FEEDBACK
~nn@AUD-LVLio_mode,io_index,vol_level<CR><LF>
io_mode Input/Output
1 Output
io_index Number that indicates
the specific input or output port: 1
vol_level Volume level 0 to 100
++ (increase current value by 1dB);
-- (decrease current value by 1dB)
Set audio level to 50:
#AUD-LVL1,1,50<CR>
AUD-LVL?
Get volume level.
COMMAND
#AUD-LVL?io_mode,io_index<CR>
FEEDBACK
~nn@AUD-LVLio_mode,io_index,vol_level<CR><LF>
io_mode Input/Output
1 Output
io_index Number that indicates
the specific input or output port: 1
vol_level Volume level 0 to 100
Get audio output level
#AUD-LVL?1,1<CR>
AV-SW-
MODE
Set input auto switch
mode (per output).
COMMAND
#AV-SW-MODElayer_type,out_index,connection_mode<CR>
FEEDBACK
~nn@AV-SW-MODElayer_type,out_index,connection_mode<CR><
LF>
layer_type Number that
indicates the signal type:
1 Video
out_index Number that
indicates the specific output: 1
connection_mode Connection
mode
0 manual
2 last connected switch
Set input auto switch mode
(per output) to Manual:
#AV-SW-MODE1,1,0<CR>
AV-SW-
MODE?
Get input auto switch
mode (per output).
COMMAND
#AV-SW-MODE?layer_type,out_index<CR>
FEEDBACK
~nn@AV-SW-MODElayer_type,out_index,connection_mode<CR><
LF>
layer_type Number that
indicates the signal type:
1 Video
out_index Number that
indicates the specific output: 1
connection_mode Connection
mode
0 manual
2 last connected switch
Get the input audio switch
mode:
#AV-SW-MODE?1,1<CR>
BUILD-
DATE?
Get device build date.
COMMAND
#BUILD-DATE?<CR>
FEEDBACK
~nn@BUILD-DATEdate,time<CR><LF>
date Format: YYYY/MM/DD
where
YYYY = Year
MM = Month
DD = Day
time Format: hh:mm:ss where
hh = hours
mm = minutes
ss = seconds
Get the device build date:
#BUILD-DATE?<CR>
CEC
Set display to ON/OFF
COMMAND
#CECstate<CR>
FEEDBACK
~nn@CECstate<CR><LF>
state CEC state
0 Off
1 On
Set display to OFF via CEC:
#CEC-ON<CR>
CEC-PASS
Set CEC device bypass.
COMMAND
#CEC-PASSstate<CR>
FEEDBACK
~nn@CEC-PASSstate<CR><LF>
state CEC state
0 Off
1 On
Set bypass device state:
#CEC-PASS1<CR>
CEC-PASS?
Get CEC device bypass
state.
COMMAND
#CEC-PASS?<CR>
FEEDBACK
~nn@CEC-PASSstate<CR><LF>
state CEC state
0 Off
1 On
Get bypass device state:
#CEC-PASS?<CR>

Other manuals for Kramer KIT-400