KIT-400 – Protocol 3000
87
Function
Description
Syntax
Parameters/Attributes
Example
HELP
Get command list or
help for specific
command.
COMMAND
#HELP<CR>
#HELPcmd_name<CR>
FEEDBACK
1. Multi-line:
~nn@Devicecmd_name,cmd_name…<CR><LF>
To get help for command use: HELP (COMMAND_NAME)<CR><LF>
~nn@HELPcmd_name:<CR><LF>
description<CR><LF>
USAGE:usage<CR><LF>
cmd_name – Name of a specific
command
Get the command list:
#HELP<CR>
To get help for
AV-SW-TIMEOUT:
HELPav-sw-timeout<CR
>
IMAGE-
PROP
Set the image size.
COMMAND
#IMAGE-PROPscaler_index,prop<CR>
FEEDBACK
~nn@IMAGE-PROPscaler_index,prop<CR><LF>
scaler_index – Scaler number: 1
prop –
0 – Overscan
1 – Full
2 – Best fit
3 – Panscan
4 – Letterbox
5 – Underscan 2
6 – Underscan 1
7 – Follow in
Set the image size to
Letterbox:
#IMAGE-PROP1,4<CR>
IMAGE-
PROP?
Get the image size.
COMMAND
#IMAGE-PROP?scaler_index<CR>
FEEDBACK
~nn@IMAGE-PROPscaler_index,prop<CR><LF>
scaler_index – Scaler number: 1
prop –
0 – Overscan
1 – Full
2 – Best fit
3 – Panscan
4 – Letterbox
5 – Underscan 2
6 – Underscan 1
7 – Follow in
Get mute status of the output
#IMAGE-PROP?1<CR>
LOCK-FP
Lock the front panel.
COMMAND
#LOCK-FPlock/unlock<CR>
FEEDBACK
~nn@LOCK-FPlock/unlock<CR><LF>
lock/unlock –
0 – Unlock
1 – Lock
Lock front panel buttons:
#LOCK-FP1<CR>
LOCK-FP?
Get the front panel lock
state.
COMMAND
#LOCK-FP?<CR>
FEEDBACK
~nn@LOCK-FPlock/unlock<CR><LF>
lock/unlock –
0 – Unlocked
1 – Locked
Get front panel lock state
#LOCK-FP?<CR>
MODEL?
Get device model.
This command
identifies equipment
connected to KIT-400
and notifies of identity
changes to the
connected equipment.
The Matrix saves this
data in memory to
answer REMOTE-INFO
requests.
COMMAND
#MODEL?<CR>
FEEDBACK
~nn@MODELmodel_name<CR><LF>
model_name – String of up to 19
printable ASCII chars
Get the device model:
#MODEL?<CR>
MUTE
Set audio mute.
COMMAND
#MUTEout_index,mute_mode<CR>
FEEDBACK
~nn@MUTEout_index,mute_mode<CR><LF>
out_index – Number that
indicates the specific output: 1
mute_mode – On/Off
0 – Off
1 – On
Set the output to mute:
#MUTE1,1<CR>
MUTE?
Get audio mute.
COMMAND
#MUTE?out_index<CR>
FEEDBACK
~nn@MUTEout_index,mute_mode<CR><LF>
out_index – Number that
indicates the specific output: 1
mute_mode – On/Off
0 – Off
1 – On
Get mute status of the output
#MUTE?1<CR>
PROT-VER?
Get device protocol
version.
COMMAND
#PROT-VER?<CR>
FEEDBACK
~nn@PROT-VER3000:version<CR><LF>
version – XX.XX where X is a
decimal digit
Get the device protocol
version:
#PROT-VER?<CR>
RELAY-
STATE
Set relay state.
COMMAND
#RELAY-STATErelay_id,state<CR>
FEEDBACK
~nn@RELAY-STATErelay_id,state<CR><LF>
relay_id – Relay number: 1
state – Relay state
0 – (open)
1 – (close)
Set relay 1 to closed:
#RELAY-STATE1,1<CR>
RELAY-
STATE?
Get relay state.
COMMAND
#RELAY-STATE?relay_id<CR>
FEEDBACK
~nn@RELAY-STATErelay_id,relay_state<CR><LF>
relay_id – Relay number 1
relay_state – Relay state
0 – (open)
1 – (close)
Get relay state:
#RELAY-STATE?1<CR>
RESET
Reset device.
To avoid locking the
port due to a USB bug
in Windows, disconnect
USB connections
immediately after
running this command.
If the port was locked,
disconnect and
reconnect the cable to
reopen the port.
COMMAND
#RESET<CR>
FEEDBACK
~nn@RESETok<CR><LF>
Reset the device:
#RESET<CR>