1 2 3 4
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
6.6.2 Setting the MACHINE ADDRESS #
The MACHINE ADDRESS # is determined via the MACHINE
ADDRESS Menu command, as section
8.3 describes. The MACHINE
ADDRESS # defines which inputs and outputs are configured to that
particular unit when expanding, as the chart in
Figure 7 illustrates.
A valid MACHINE ADDRESS # is from 1 to 36.
6.6.3 Understanding the SYSTEM Mode
DIP 5 defines whether the VS-1616A unit communicates with other
switchers via a common control line.
You can set DIP 5 OFF to disable the Follow-SYSTEM mode in the
following applications:
• Stand alone switcher applications
1
• A multi-channel audio switcher application
2
• An expanded matrix switcher application
3
You must set DIP 5 ON to enable the Follow-SYSTEM mode in an
interconnected varied-format switcher application
1
1 See section
and to allow control
from a PC via RS-232 or RS-485 using the K-Router application.
6.2
2 See section
6.3
3 See section
6.4