7.2.1.1 Toggling between the AT ONCE and CONFIRM Modes
To toggle between the AT ONCE (default) mode and the CONFIRM
mode, press the TAKE button.
In CONFIRM mode: Actions require user confirmation and the TAKE
LED lights.
In AT ONCE mode: Actions do not require user confirmation and the
TAKE LED does not light.
When the TAKE LED blinks:
• You cannot toggle between the AT ONCE and CONFIRM
modes
• You can execute the previous action, by pressing the TAKE
button
• You can cancel the previous action, by pressing a non-relevant
button (for example, the MENU button)
7.2.2 Switching Inputs to Outputs
You can switch:
• One input to one output (see section
7.2.2.1
)
• Several inputs to several outputs (see section
7.2.2.2)
• One input to all outputs (see section
7.2.2.3)
7.2.2.1 Switching One Input to One Output
Pressing an OUT-IN combination when your VS-1616A operates in the
AT ONCE mode implements the switch immediately.
To switch one input to one output (AT ONCE mode):
1. Press the appropriate OUT button.
The MATRIX Display shows the 2 blinking digits, representing the
present input number connected to that specific output
1
out # x
. If the present
output is clear, the 2 blinking digits 00 appear in the MATRIX Display.
The STATUS Display shows the message:
Where x is the output number
2. Press the appropriate IN button.
The output switches to the input and the MATRIX Display shows the
1 For example, pressing OUT button 9 shows the blinking digits 01 if input 1 was previously routed to OUT 9