Pos: 25.26.27 /Überschriften/Überschriften 3/K-O/MMesserschnellverschluss @ 0\mod_1197271019859_78.docx @ 16597 @ 3 @ 1
10.9.2 Blade Quick-Fit Device
Pos: 25.26.28 /BA/Wartung/Mähwerke/Messerschraub / Messerschnellverschluss/Beschreibung Messerwechsel Messerschnellverschluss @ 0\mod_1197271100500_78.docx @ 16616 @ @ 1
EC-251-0
3 4
2
5
Fig.
33
Clean the area.
Remove damaged or worn blades.
Push the special tool (1) {blade key} between the cutter disc (4) and leaf spring (3) and
press down with one hand.
Guide a new blade (2) onto the retaining bolt and allow the blade key to return upwards.
After fitting the blades, fold the protective device down again.
Note
The cutter blades of anticlockwise rotating cutting discs / blade drums are different than
those of clockwise rotating ones. Make certain the direction of rotation is correct when
installing!
The arrow on the cutter blades must match the direction of rotation of the corresponding
cutting discs / blade drums.
The hex nut (4) used to secure the retaining bolts must not be used more than once.
Order No. for clockwise rotating blade: 139-889
Order No. for anticlockwise rotating blade: 139-888