5 Installation/ Commissioning
28 of 50
KSB Guard
4079.83/01-EN
5.3 Assigning and setting up
NOTE
The sensor unit must be initially assigned to a pump set.
This assignment cannot be subsequently undone and remains valid for the service
life of the sensor unit.
Correct assignment is key to ensuring proper functionality of the device.
Measurement data can only be saved after the assignment has been made.
You can make the assignment on the KSBGuard web portal (www.ksbguard.net) or
in the KSBGuard app (available for iOS and Android).
5.3.1 Data required for adding a pump set
To add a pump, further pump set data is required. We recommend that you collect
the data in advance so that it is readily available when you need it. The following
data is required:
Table11: Data required for adding a pump set
Required data Example Notes
Serial number of the sensor unit GS118W220071
Designation of the pump set Pump 123
Location of the pump set Hall 2
Functional location of the pump set B2411
Optional: Photo of the pump (set)
Data from the pump name plate
Manufacturer KSB
Year of construction 2018
Serial number
3)
997123456700010000
Type series Etanorm
Size 050-032-161
Nominal head 25m
Nominal flow rate 50m³/h
Nominal speed 1450rpm
Number of stages 1
Operating hours of the pump set to date (initial
value for the operating hours counter)
1000h
Data from the motor name plate
Nominal power 15kW
Nominal speed 1450rpm
Power factor (cosϕ) 0,86
Other details
Variable speed system (yes or no) No
Application of the pump Heat supply system
Fluid temperature +20°C to +30°C
Density of the fluid handled 997kg/m³
Bearing type and, if applicable, operating hours
since most recent bearing lubrication/ bearing
replacement
Grease, re-lubrication, 1000h
3
With a pump set from KSB, data on the pump can be accessed when necessary. To do so, enter the KSB serial
number in the corresponding field of the app/ web portal. If data is available, it will be displayed in the app or
on the web portal and must be checked to ensure that it is accurate and up to date.