7 Servicing/Maintenance
52 of 80
HPK
1121.8/06-EN
DANGER
Risk of potentially explosive atmosphere inside the pump
Explosion hazard!
The pump internals in contact with the fluid to be handled, including the seal
chamber and auxiliary systems, must be filled with the fluid to be handled at all
times.
Provide sufficient inlet pressure.
Provide an appropriate monitoring system.
CAUTION
Increased wear due to dry running
Damage to the pump set!
Never operate the pump set without liquid fill.
Never close the shut-off element in the suction line and/or supply line during
pump operation.
CAUTION
Impermissibly high temperature of fluid handled
Damage to the pump!
Prolonged operation against a closed shut-off element is not permitted
(heating up of the fluid).
Observe the temperature limits in the data sheet and in the section on
operating limits. (ðSection6.2,Page46)
While the pump is in operation, observe and check the following:
The pump must run quietly and free from vibrations at all times.
In case of oil lubrication, ensure the oil level is correct. (ðSection6.1.2,Page37)
Check the shaft seal.
Check the static sealing elements for leakage.
Check the rolling element bearings for running noises.
Vibrations, noise and an increase in current input occurring during unchanged
operating conditions indicate wear.
Monitor the correct functioning of any auxiliary connections.
Cooling system
Take the pump out of service at least once a year to thoroughly clean the cooling
system.
Monitor the stand-by pump.
To make sure that stand-by pumps are ready for operation, start them up once a
week.
Monitor the bearing temperature.
The bearing temperature must not exceed 90 °C (measured on the outside of the
bearing bracket).
CAUTION
Operation outside the permissible bearing temperature
Damage to the pump!
The bearing temperature of the pump (set) must never exceed 90 °C (measured
on the outside of the bearing bracket).