EasyManuals Logo

KSB HPK Series User Manual

KSB HPK Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
7 Servicing/Maintenance
54 of 80
HPK
1121.8/06-EN
7.2.2.3 Cleaning filters
CAUTION
Insufficient inlet pressure due to clogged filter in the suction line
Damage to the pump!
Monitor contamination of filter with suitable means (e.g. differential pressure
gauge).
Clean filter at appropriate intervals.
7.2.3 Lubrication and lubricant change of rolling element bearings
DANGER
Excessive temperatures as a result of bearings running hot or defective bearing
seals
Explosion hazard!
Fire hazard!
Damage to the pump set!
Regularly check the condition of the lubricant.
7.2.3.1 Oil lubrication
The rolling element bearings are usually lubricated with mineral oil.
7.2.3.1.1 Intervals
Table22: Oil change intervals
Temperature at the
bearing
First oil change All subsequent oil
changes
10)
Up to 70°C After 300 operating hours Every 8,500 operating
hours
70°C - 80°C After 300 operating hours Every 4,200 operating
hours
80°C - 90°C After 300 operating hours Every 2,000 operating
hours
7.2.3.1.2 Oil quality
Oil quality Table23: Oil quality
Description Symbol to
DIN51502
Properties
CLP46 lubricating oil
to DIN51517
or
HD20W/20 SAE
Kinematic viscosity
at40°C
46±4 mm²/s
Flash point (to
Cleveland)
+175°C
Solidification point
(pour point)
-15°C
Application
temperature
11)
Higher than
permissible bearing
temperature
10
At least once a year
11
For ambient temperatures below -10 °C use a different suitable type of lubricating oil. Contact KSB.