8 Trouble-shooting
68 of 80
HPK
1121.8/06-EN
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷ For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB service is required.
A Pump delivers insufficient flow rate
B Motor is overloaded
C Excessive discharge pressure
D Increased bearing temperature
E Leakage at the pump
F Excessive leakage at the shaft seal
G Vibrations during pump operation
H Impermissible temperature increase in the pump
Table31: Trouble-shooting
A B C D E F G H Possible cause
Remedy
18)
✘ - - - - - - - Pump delivers against an excessively
high pressure.
Re-adjust to duty point.
Check system for impurities.
Fit a larger impeller.
19)
Increase the speed (turbine, I.C. engine).
✘ - - - - - ✘ ✘ Pump or piping are not completely
vented or primed.
Vent and/or prime.
✘ - - - - - - - Supply line or impeller clogged Remove deposits in the pump and/or piping.
✘ - - - - - - - Formation of air pockets in the piping Alter piping layout.
Fit vent valve.
✘ - - - - - ✘ ✘ Suction lift is too high/NPSH
available
(positive suction head) is too low.
Check/alter fluid level.
Install pump at a lower level.
Fully open the shut-off element in the suction
line.
Change suction line, if the friction losses in
the suction line are too high.
Check any strainers installed/suction opening.
Observe permissible speed of pressure fall.
✘ - - - - - - - Air intake at the shaft seal Clean barrier fluid duct, supply external
barrier fluid, if necessary, or increase barrier
fluid pressure.
Replace shaft seal.
✘ - - - - - - - Wrong direction of rotation Check the electrical connection of the motor
and the control system, if any.
✘ - - - - - - -
Speed is too low.
19)
- Operation with frequency inverter
- Operation without frequency inverter
- Increase voltage/frequency at the frequency
inverter in the permissible range.
- Check voltage.
✘ - - - - - ✘ - Impeller Replace worn components by new ones.
18
Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
19
Contact KSB.