8 Operating the Pressure Booster System
28 of 44
Hya-Solo DSV
Table17: Parameters for display language
Parameter Description Possible settings Factory setting
3-1-1 Language
Configurable display language
Depending on the language package:
English, German, French, Italian
English, French, Dutch, Danish
English, Spanish, Portuguese, Turkish
English, Norwegian, Swedish, Finnish
English, Estonian, Latvian, Lithuanian
English, Polish, Hungarian, Czech
English, Slovenian, Slovakian, Croatian
English, Russian, Romanian, Serbian
English, German,
French, Italian
8.1.2.3.2 Setting the control panel
Table18: Parameters for setting the control panel
Parameter Description Possible settings Factory setting
3-1-2-1 Operating Values on Main Screen
Display of current operating values on the main
screen
Main screen selection list -
3-1-2-2 Control Keys Require Login
Direct access to the MAN, OFF, AUTO and FUNC
operating keys can be disabled via this parameter.
OFF
ON
OFF
3-1-2-3 Function Key Assignment
Assigning a freely selectable function to the FUNC
key
No Function
System Start / Stop
Setpoint (Closed-loop
Control)
Control Value (Open-loop
Control)
Alternative Setpoint (Closed-
loop Control)
Alternative Control Value
(Open-loop Control)
Immediate Pump
Changeover
Immediate Functional Check
Run
Language
Fixed Speed 1
PumpMeter Upload
Remote/Local Control Point
Language
3-1-2-4 Display Contrast
Configurable contrast for the display
0...100 50
3-1-2-5 Display Backlight
Configuring the display backlight
OFF
ON
Automatic
Automatic
3-1-2-6 Display Backlight Duration
Duration of display backlight on period in
automatic mode
0...600 30
Operating Values on Main
Screen
Up to 4operating values are simultaneously displayed on the main screen. An
operating value is displayed in large format with the associated parameter name,
parameter number and unit. Three (3) operating values are displayed in smaller
format with the associated unit. The arrow keys can be used to cycle through the
operating values. Each operating value passes through all display areas. Up to

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Hya-Solo DSV Series and is the answer not in the manual?

KSB Hya-Solo DSV Series Specifications

General IconGeneral
BrandKSB
ModelHya-Solo DSV Series
CategoryWater Pump
LanguageEnglish

Related product manuals