10 Trouble-shooting
35 of 44
Hya-Solo DSV
A B C D E F G H I J K L M Possible cause Remedy
1)
- - - - - - - Incorrect power supply; wrong
speed.
Check power supply.
- - - - - Shut-off valves (partially) closed Check, open as necessary.
- - - - - - - - Pump and/or piping are not
completely vented or primed.
Vent and/or prime.
- - - - - - Check valve in bypass line defective Replace.
- - - - - - - - - - - - Insufficient inflow Restore required inflow; connect
inlet tank.
- - - - - - - - - Pump runs sluggishly. Have pump repaired by a
specialist.
- - - - - - - - - - - - Defective mechanical seal Replace.
- - - - - - - - - - Incorrect pre-charge pressure of
accumulator
Set correct pre-charge pressure;
replace membrane.
- - - - - - - - Inlet-side pressure switch defective
or set incorrectly.
Check/correct the value set at the
pressure switch.
- - - - - - - - - Defective time-lag relay or time set
incorrectly.
Check time-lag relay/correct
minimum operating time.
- - - - - - - - - - - - System leaking. Restore system integrity.
- - - - - - - - Discharge-side pressure switch
defective or set incorrectly.
Check/correct the value set at the
pressure switch.
- - - - - - - - - - - Intermittent voltage fluctuations Press reset/fault acknowledgement
key.
- - - - - - - - - Defective check valve in the
pressure booster system
Check; fit new valve if required.
- - - - - - - - Pump running in the wrong
direction of rotation.
Interchange two phases of the
power cable.
- - - - - - - - - Inlet pressure lower than stated in
the purchase order
Connect inlet tank, contact KSB.
- - - - - - - - - Water extraction higher than
stated in the purchase order
Contact KSB.
10.2 Trouble-shooting: frequency inverter
WARNING
Improper work to remedy faults
Risk of injury!
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB customer service is required.
A
Mains fuse rating too small for the nominal mains current.
B
Motor does not start.
C
Motor running unevenly.
D
Max. speed not reached.
E
Motor running at maximum speed only.
F
Motor running at minimum speed only.
G
No/faulty 24V supply.
H
Wrong direction of rotation of the motor.
I
Fault message/protective tripping.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Hya-Solo DSV Series and is the answer not in the manual?

KSB Hya-Solo DSV Series Specifications

General IconGeneral
BrandKSB
ModelHya-Solo DSV Series
CategoryWater Pump
LanguageEnglish

Related product manuals