EasyManuals Logo

KSB Omega User Manual

KSB Omega
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
DANGER
Excessive temperatures due to dry running
Explosion hazard!
Fire hazard!
Damage to the pump set!
Never operate the pump set without liquid fill.
Never close the shut-off element in the suction line and/or supply line during
pump operation.
CAUTION
Impermissibly high temperature of fluid handled
Damage to the pump!
Prolonged operation against a closed shut-off element is not permitted
(heating up of the fluid).
Observe the temperature limits in the data sheet and in the section on
operating limits. (Section 6.2 Page 43)
CAUTION
Corrosion caused by stagnant aggressive fluids, e.g. fluids containing chloride
Damage to the pump!
Every 24 hours operate the pump for a minimum of 30 minutes or flush it with
clean, pure water.
11)
While the pump is in operation, observe and check the following:
The pump must run quietly and free from vibrations at all times.
Check the shaft seal. (Section 6.1.4 Page 42)
Check the static sealing elements for leakage.
Check the rolling element bearings for running noises.
Vibrations, noise and an increase in current input occurring during unchanged
operating conditions indicate wear.
Monitor the correct functioning of any auxiliary connections.
Monitor the stand-by pump.
To make sure that stand-by pumps are ready for operation, start them up once a
week.
Monitor the bearing temperature.
The bearing temperature must not exceed 90 °C (measured on the outside of the
bearing bracket).
Check the flexible elements of the coupling and replace them, if required.
Check any pressure gauges.
Check the drive as described in the manufacturer's product literature.
Check that the fitted coupling guard does not touch the coupling.
Make sure that the earth connection has been fitted and marked.
CAUTION
Operation outside the permissible bearing temperature
Damage to the pump!
The bearing temperature of the pump (set) must never exceed 90 °C (measured
on the outside of the bearing bracket).
11)
E.g. drinking water or demineralised water
7 Servicing/Maintenance
Omega / Omega V
49 of 94

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Omega and is the answer not in the manual?

KSB Omega Specifications

General IconGeneral
ApplicationWater supply, irrigation
Operating pressureUp to 16 bar
Speed2900 rpm, 1450 rpm
Connection SizeDN 32 to DN 400
Housing MaterialCast iron, stainless steel
Impeller MaterialBronze, stainless steel, cast iron
Seal TypeMechanical seal
Operating Temperature-10°C to +120°C

Related product manuals