EasyManuals Logo

KSB Omega User Manual

KSB Omega
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
CAUTION
Welding beads, scale and other impurities in the piping
Damage to the pump!
Free the piping from any impurities.
If necessary, install a filter.
Comply with the instructions set out in (Section 7.2.2.4 Page 52) .
4. If required, install a filter in the piping.
5. Connect the pump nozzles to the piping.
CAUTION
Aggressive flushing and pickling agents
Damage to the pump!
Match the cleaning operation mode and duration for flushing and pickling
service to the casing and seal materials used.
5.5 Enclosure/insulation
WARNING
Failure to re-install or re-activate protective devices
Risk of injury from moving parts or escaping fluid!
As soon as the work is completed, re-install and/or re-activate any safety-
relevant and protective devices.
CAUTION
Heat build-up in the bearing housing
Damage to the bearing!
Never insulate the bearing housing and bearing cover.
5.6 Aligning the pump and motor
DANGER
Inadmissible temperatures at the coupling or bearings due to misalignment of the
coupling
Explosion hazard!
Risk of burns!
Make sure that the coupling is correctly aligned at all times.
CAUTION
Misalignment of pump and motor shafts
Damage to pump, motor and coupling!
Always check the coupling after the pump has been installed and connected to
the piping.
Also check the coupling of pump sets supplied with pump and motor mounted
on the same baseplate.
5 Installation at Site
32 of 94
Omega / Omega V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Omega and is the answer not in the manual?

KSB Omega Specifications

General IconGeneral
ApplicationWater supply, irrigation
Operating pressureUp to 16 bar
Speed2900 rpm, 1450 rpm
Connection SizeDN 32 to DN 400
Housing MaterialCast iron, stainless steel
Impeller MaterialBronze, stainless steel, cast iron
Seal TypeMechanical seal
Operating Temperature-10°C to +120°C

Related product manuals