Never operate the pump without the fluid to be handled.
Observe the minimum flow rates indicated in the data sheet or product literature
(to prevent overheating, bearing damage, etc).
Observe the maximum flow rates indicated in the data sheet or product
literature (to prevent overheating, mechanical seal damage, cavitation damage,
bearing damage, etc).
Do not throttle the flow rate on the suction side of the pump (to prevent
cavitation damage).
Consult the manufacturer about any use or mode of operation not described in
the data sheet or product literature.
Prevention of foreseeable misuse
Never open the discharge-side shut-off elements further than permitted.
The maximum flow rates specified in the product literature or data sheet
would be exceeded.
Risk of cavitation damage
Never exceed the permissible operating limits specified in the data sheet or
product literature regarding pressure, temperature, etc.
Observe all safety information and instructions in this manual.
2.4 Personnel qualification and training
All personnel involved must be fully qualified to transport, install, operate, maintain
and inspect the machinery this manual refers to.
The responsibilities, competence and supervision of all personnel involved in
transport, installation, operation, maintenance and inspection must be clearly
defined by the operator.
Deficits in knowledge must be rectified by means of training and instruction
provided by sufficiently trained specialist personnel. If required, the operator can
commission the manufacturer/supplier to train the personnel.
Training on the pump (set) must always be supervised by technical specialist
personnel.
2.5 Consequences and risks caused by non-compliance with this manual
Non-compliance with this operating manual will lead to forfeiture of warranty
cover and of any and all rights to claims for damages.
Non-compliance can, for example, have the following consequences:
Hazards to persons due to electrical, thermal, mechanical and chemical
effects and explosions
Failure of important product functions
Failure of prescribed maintenance and servicing practices
Hazard to the environment due to leakage of hazardous substances
2.6 Safety awareness
In addition to the safety information contained in this manual and the intended use,
the following safety regulations shall be complied with:
Accident prevention, health and safety regulations
Explosion protection regulations
Safety regulations for handling hazardous substances
Applicable standards, directives and laws
2 Safety
Omega / Omega V
9 of 94

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Omega and is the answer not in the manual?

KSB Omega Specifications

General IconGeneral
ApplicationWater supply, irrigation
Operating pressureUp to 16 bar
Speed2900 rpm, 1450 rpm
Connection SizeDN 32 to DN 400
Housing MaterialCast iron, stainless steel
Impeller MaterialBronze, stainless steel, cast iron
Seal TypeMechanical seal
Operating Temperature-10°C to +120°C