7.5 Reassembling the pump set
7.5.1 General information/Safety regulations
DANGER
The pump (set) could slip out of the suspension arrangement
Danger to life from falling parts!
Always transport the pump (set) in the specified position.
Never attach the suspension arrangement to the free shaft end or the motor
eyebolt.
Give due attention to the weight data and the centre of gravity.
Observe the applicable local health and safety regulations.
Use suitable, permitted lifting accessories, e.g. self-tightening lifting tongs.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
WARNING
Unqualified personnel performing work on the pump (set)
Risk of injury!
Always have repair and maintenance work performed by specially trained,
qualified personnel.
WARNING
Unintentional starting of pump set
Risk of injury by moving parts!
Ensure that the pump set cannot be started up unintentionally.
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.
WARNING
Components heated up for installation
Risk of burns to hands!
Wear protective gloves suitable for installation work.
Let components cool down after installation.
CAUTION
Improper reassembly
Damage to the pump!
Reassemble the pump (set) in accordance with the general rules of sound
engineering practice.
Use original spare parts only.
Always observe the safety instructions and information. (Section 2.8 Page 10)
For any work on the motor, observe the instructions of the relevant motor
manufacturer.
For dismantling and reassembly, refer to the general assembly drawing.
In the event of damage, you can always contact our service department.
7 Servicing/Maintenance
60 of 94
Omega / Omega V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB Omega and is the answer not in the manual?

KSB Omega Specifications

General IconGeneral
ApplicationWater supply, irrigation
Operating pressureUp to 16 bar
Speed2900 rpm, 1450 rpm
Connection SizeDN 32 to DN 400
Housing MaterialCast iron, stainless steel
Impeller MaterialBronze, stainless steel, cast iron
Seal TypeMechanical seal
Operating Temperature-10°C to +120°C

Related product manuals