EasyManua.ls Logo

Kubota KX080-3 - Servicing as Required; Checking Amount of Refrigerant (Gas)

Kubota KX080-3
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77REGULAR CHECKS AND MAINTENANCE WORK
SERVICING AS REQUIRED
BChecking Amount of Refrigerant (gas)
To avoid personal injury:
A Liquid contact with eyes or skin may cause
frostbite.
A In the event of a leakage, wear safety goggles.
Escaping refrigerant can cause severe injuries
to eyes.
A In contact with a flame, R134a refrigerant gives
a toxic gas.
A Do not disconnect any part of the
refrigeration circuit of the air conditioning
system. Consult your local KUBOTA Dealer for
assistance and service.
A shortage of refrigerant impairs the air-conditioner
performance. Check the following points. If it is indicated
that the amount of refrigerant is extremely low, ask your
dealer to inspect and charge.
C Checking procedure
1. Run the air-conditioner in the following conditions.
2. Look into the sight glass to see if the refrigerant is
flowing through its circuit.
A Charge only with R134a not R12 refrigerant (gas).
A Engine speed: About 1500 rpm
A Temperature control lever: Maximum cooling
position (rightmost)
A Fan switch: Highest blow (3)
A Air-conditioner switch: ON
(1) Sight glass

Table of Contents

Other manuals for Kubota KX080-3

Related product manuals