EasyManua.ls Logo

Kuka IONTEC KR 70 R2100 F - 8.4 Oil Change in A2

Kuka IONTEC KR 70 R2100 F
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 8-5: Filling gear unit A1 with gear oil
1 M18x1.5 magnetic screw plug for venting
2 Inspection hole = vent hole
3 Oil drain hole with M18x1.5 magnetic screw plug
8.3.3 Concluding work
The following concluding work must be carried out:
Remove oil residue.
Visual inspection, check for leaks.
Run the program in T1 mode and look out for irregularities.
8.4 Oil change in A2
Description
The following sections describe the A2 gear oil change for floor-mounted
robots. For ceiling-mounted robots, the procedure is to be applied analo-
gously, but with the drain and filler holes reversed.
Equipment
The following equipment is required:
Designation Article number
Set of Allen keys
1.5; 2; 2.5; 3; 4; 5; 6; 8; 10 mm
-
Torque wrench
min. 2 Nm to 30 Nm
-
Socket wrench set -
Collection receptacle -
KUKA oil pump 0000-180-812
Oil drain tube - M18x1.5 0000-265-680
Material
The following material is required:
KR IONTEC
200/344 | www.kuka.com MA KR IONTEC V4 | Issued: 11.05.2021
Maintenance

Table of Contents

Related product manuals