12. COOLING SYSTEM
12-12
Mongoose/KXR 250
THERMOSTAT INSPECTION
Suspend the thermostat in a pan of water
over a burner and gradually raise the water
temperature to check its operation.
Technical Data
Begins to open 80±2℃
Full-open 90℃
Valve lift 3.5~4.5mm
THERMOSTAT INSTALLATION
The installation sequence is the reverse of
removal.
Fill the cooling system with the specified
coolant. (
Ö
3-20)
O-ring
Thermosenso
• Do not let the thermostat touch the pan
as it will give a false reading.
• Replace the thermostat if the valve
stays open at room temperature.
•Test the thermostat after it is opened for
about 5 minutes and holds the
temperature at 70℃.
*
Replace the O-ring with a new one and
apply grease to it.
*