2K5
1-3-55
U203
Checking DP operation
Description
Simulates the original conveying operation separately in the DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP if running this simulation with paper.
3. Select the item to be operated.
4. Press the start key. The operation starts.
5. To stop continuous operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U204
Setting the presence or absence of a key card or key counter
Description
Sets the presence or absence of the optional key card or key counter.
Purpose
To run this maintenance item if a key card or key counter is installed.
Method
1. Press the start key.
2. Select the item to be set. The setting screen for the selected item is displayed.
Setting: [KEY-DEVICE]
1. Select the optional counter to be installed.
Initial setting: OFF
2. Press the start key. The setting is set.
3. Turn the main power switch off and on.
Setting: [MESSAGE]
1. Select the [KEY-DEVICE] or [COIN VENDOR].
2. Press the start key. The setting is set.
3. Turn the main power switch off and on.
Maintenance
item No.
Description
Display Description Setting range Initial setting
CCD ADP
(NON P)
Without paper, single-sided original
(continuous operation)
--
CCD ADP With paper, single-sided original - -
CCD RADP
(NON P)
Without paper, double-sided original
(continuous operation)
--
CCD RADP With paper, double-sided original - -
SPEED
Switching between normal reading (600 dpi)
and high-speed reading
0 (Normal)/
1 (High-speed)
0
Display Description
KEY-DEVICE Sets the presence or absence of the key card or key counter
MESSAGE Sets the message when optional equipment is not installed
Display Description
KEY-CARD The key card is installed
KEY-COUNTER The key counter is installed
OFF Not installed