SmartShop|Maker Owner’s Manual
40
2. Check the dust extraction for blockages as large pieces could cause blockages.
3. Verify the electrical connectors are fitted tightly and correctly.
8.6 Common Error Codes
Error Code Potential Issue(s) Resolution(s)
EMERGENCY STOP ALARM
The Emergency Stop button has
been pressed and not reset.
Release the Emergency Stop
button by turning it clockwise.
Low Air
Air pressure is below the threshold
(recommended at 67 bar)
1. Verify the air turned on.
2. Verify all air lines are
securely connected.
No Tool There tool loaded in the spindle. Load a tool in the spindle.
Over Travel
The spindle has moved beyond the
parameters of the project program.
1. Verify the machine is
homed.
2. Verify the proper program
has been selected.
Spindle 1 brusher rise is not
in place alarm
1. The airlines are swapped.
2. The dust head sensor is out of
place.
The dust head is down.
1. Verify the airline
connections.
2. Properly reposition the dust
head sensor.
3. Raise the dust head.
Syntax Error Programming error.
Check program syntax
according to symbol appears on
the screen.
X, Y, or Z not yet back home The machine is not homed. Home the machine.

Related product manuals