84
90024570rev00
90024570rev00
84
90024570rev00
The main fault warning messages
are indicated on the display with the
appearance of an alarm window.
The type of fault identified is indicated
on the second line of the alarm window.
NON SERIOUS alarms are:
OVERTEMP. WASHING
Error during the wash phase.
It appears when the oven temperature
is too high during the MAN, SOFT or
HARD wash phase.
Switch off the oven and wait for it to
cool. If the problem persists call the
manufacturer technician or authorized
service agent.
NO H2O
This means there is no water: check
that the shutoff valve is open and that
there is water still coming from the main.
If there is no supply from the main,
inform the water company or agency.
If there is no problem with the main,
contact a manufacturer technician or
authorized service agent.
BOILER PROBE
(if oven not cooking or
preheating, or convection cooking).
Boiler pre-heating probe fault, oven
can only be operated in convection
mode; Steam and Combined modes
are disabled. Call in the technical
assistance service.
CORE PROBE
Core probe faulty. Should the message
appear, it is necessary to check the
connector is plugged into the socket
(10) properly. The oven can continue
to be used until the arrival of a service
technician, but without this accessory.
ATTENTION
Core temp. Probe
!!
BOILER PROBE
(If oven cooking in
steam mode, combined or preheating
boiler).
Boiler pre-heating probe fault, oven
can only be operated in convection
mode;Steam and Combined modes
are disabled. Call in the technical
assistance service.
CONDENSATION PROBE
(If oven
cooking in steam or combined mode).
Vapour condensation temperature
probe faulty. The condenser is in
operation continuously, but the oven can
still be used under close observation
in convection mode until the arrival of
a service technician.
24.2 - NON SERIOUS ALARM
23 SELF-DIAGNOSIS AND FAULT IDENTIFICATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lainox Heart X and is the answer not in the manual?

Lainox Heart X Specifications

General IconGeneral
BrandLainox
ModelHeart X
CategoryOven
LanguageEnglish

Related product manuals