8: Setup Mode: Channel Configuration
xDirect User Guide 54
unit sends immediately after recognizing the transmit condition (sendchar or timeout). The
default setting is 0.
Note: A transmission might occur if status information needs to be exchanged or an
acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the TCP connection to the local port
if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss,
where m is the number of minutes and s is the number of seconds.
DisConnTime (00:00) ?:
To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds (99 minutes,
59 seconds). Default setting is 0.
Send Characters
Enter up to two characters in hexadecimal representation in sendchar.
SendChar 1 (00) ? _
SendChar 2 (00) ? _
If the unit receives a character on the serial line that matches one of these characters, it sends the
character immediately, along with any awaiting characters, to the TCP connection. This action
minimizes the response time for specific protocol characters on the serial line (for example, ETX,
EOT). Setting the first sendchar to 00 disables the recognition of the characters. Alternatively, the
unit can interpret two characters as a sequence (see Pack Control). The default setting is 00.
Telnet Terminal Type
This parameter displays only if you enabled the terminal type option in Disconnect Mode. With this
option enabled, you can use the terminal name for the Telnet terminal type. Enter only one name.
With terminal type option enabled, the unit also reacts to the EOR (end of record) and binary
options, useful for applications like terminal emulation to IBM hosts.
Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect Mode.
With this option enabled, you can set a password on the serial port. The default setting is all 0s.

Table of Contents

Other manuals for Lantronix xDirect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix xDirect and is the answer not in the manual?

Lantronix xDirect Specifications

General IconGeneral
ManualYes
Quantity per pack1 pc(s)
Connector 1RS232/422/485
Connector 2DB9F
Connector 1 genderFemale
CertificationCE, RoHS
Product colorBlack, Silver
Sustainability certificatesRoHS
Input voltage100 - 240 V

Related product manuals