EasyManuals Logo
Home>Lantronix>Server>xDirect

Lantronix xDirect User Manual

Lantronix xDirect
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
xDirect User Guide 55
9: Setup Mode: Advanced Settings
Expert Settings (Option 5)
Note: You can change these settings using telnet or serial connections only, not on the
Web Manager.
Caution: Changing the expert settings can drastically affect the performance and
access to the product. These settings should only be changed by an
experienced network administrator.
Select 5 to configure expert settings.
Figure 9-1 Expert Settings
TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?
ARP Cache timeout in s (1s - 600s) : (600) ?
CPU performance (0=Regular, 1=Low, 2=High): (0) ?
Disable Monitor Mode @ bootup (N) ?
HTTP Port Number : (80) ?
MTU Size (512 - 1400): (1400) ?
TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?
Enable alternate MAC (N) ?
Ethernet connection type: (0) ?
TCP Keepalive Time In Seconds
This option allows you to change how many seconds the unit waits during a silent connection
before attempting to see if the currently connected network device is still on the network. If the unit
gets no response, it drops that connection. The default setting is 45.
TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?
ARP Cache Timeout In Seconds
Whenever the unit communicates with another device on the network, it adds an entry into its ARP
table. The ARP Cache timeout option allows you to define how many seconds (1-600) the unit will
wait before timing out this table. The default setting is 600.
ARP cache timeout in s (1s - 600s) : (600) ?
CPU Performance
This option allows you to increase the CPU performance required to use the higher baud rates on
the serial interface (460800 bps and 921600 bps). The default CPU performance mode supports
up to 230400 bps.
CPU performance (0=Regular, 1=Low, 2=High): (0) ?
If a baud rate of 460 Kbps or 920 Kbps is set and the high performance mode is disabled, the
operation of the serial channel would be out of the specified error tolerance, thereby leading to
inconsistent speed settings on the two ends of the serial channel.

Table of Contents

Other manuals for Lantronix xDirect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix xDirect and is the answer not in the manual?

Lantronix xDirect Specifications

General IconGeneral
ManualYes
Quantity per pack1 pc(s)
Connector 1RS232/422/485
Connector 2DB9F
Connector 1 genderFemale
CertificationCE, RoHS
Product colorBlack, Silver
Sustainability certificatesRoHS
Input voltage100 - 240 V

Related product manuals