Starting up
15.05.01
YACE0060
35
6.5.5 Other error messages
E 0 etc. is flashing in the bottom line
! various temperature probe faults.
!
pump fault, proceed as in Section 6.5.3.
If the fault report is repeated ! pull out the mains plug and try whether the motor
can be rotated by the fan blade inserting a screwdriver into the ventilation opening
at the back of the unit.
Error code 0 ...255
!
microprocessor error.
Error code 1000...1255 ! slave processor error.
Indication can be used for remote diagnosis.
After rectifying the fault, reset with the key.