8-4 Troubleshooting
Symptom
Possible cause
Action
Day planning is not set.
1. Create a day planning.
The machine swings. The gyroscope is drifting.
1. Call your local Lely service
provider.
The ultrasonic sensor does not
function correctly.
1. Clean the ultrasonic sensor.
2. Test the ultrasonic sensor.
Broken/worn tires.
1. Call your local Lely service
provider.
The machine does not stop at
the charging station.
The charging strips or electrodes
do not make contact.
1. Clean the charging strips and
the charging electrodes.
No power supply.
1. Make sure the charging
station is connected to the
power supply.
Springs that hold the electrodes
are loose.
1. Call your local Lely service
provider.
The machine does not follow the
guide strip.
The induction sensor arm is
tilted because of feed
underneath the machine.
1. Remove feed.
1. Call your local Lely service
provider.
The machine is ‘searching’ the
fence when driving Ultrasound
drive left.
Position of the ultrasound arm is
not correct.
1. Adjust the ultrasonic sensor
arm.
1. Call your local Lely service
provider.
The skirt does not rotate
smoothly.
The rubber skirt is worn out.
1. Call your local Lely service
provider.
The machine has problems with
pushing feed to the fence.
The action Ultrasound drive left
is programmed instead of Feed
push left to push the feed.
1. Call your local Lely service
provider.
Pushing intervals between the
programmed routes are too
large.
1. Program new routes with
smaller intervals (not more
than 25 cm or 9.8 in).
There was too much feed in
front of the feed fence during
programming of the routes.
1. Remove the feed and
program a new route.
The skirt of the machine does
not rotate smoothly.
1. Call your local Lely service
provider.