Cable routing for two drives with the RAID adapter
Note: The RAID adapter should be installed in PCIe slot 1.
Figure 19. Cable routing for two drives with the RAID adapter
Table 17. Cable routing for two drives with the RAID adapter
Cable
From To
1 Mini SAS HD to 4 SATA
7-pin cable
1a cable labeled as “0”
Bay 1 drive signal
connector
C0 connector on the RAID
adapter
1b cable labeled as “2”
Bay 3 drive signal
connector
2 1st 3.5 and 2.5 HDD Power Cable (300 mm + 80 mm)
Bay 2 drive power
connector* and bay 1 drive
power connector
Note: * Depending on
server configuration.
SATA power 2 connector
3 Slim ODD, second 3.5-inch drive and 2.5-inch drive
power cable ( 300 mm + 210 mm + 110 mm)
Bay 3 drive power
connector
SATA power 1 connector
Make sure to follow the “Cable routing guidelines” in “Internal cable routing” on page 19.
For the system-board connector locations, see “System board components” on page 18.
Chapter 2. Server components 27