Commissioning
The most important codes for commissioning
7
EDK82EV113 DE/EN/FR 8.1
141
L
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0002*
uSEr
Parameter set
management
−33−
0 0 Ready PAR1 ... PAR4:
l Parameter sets of the controller
l PAR1 ... PAR4 also contain
parameters for Standard−I/O,
Application−I/O, AS interface or
system bus (CAN)
FPAR1:
l Module−specific parameter set of
the fieldbus function modules
INTERBUS, PROFIBUS−DP,
LECOM−B, DeviceNet/CANopen
l FPAR1 is saved in the function
module
Restorage of
default setting
1
Lenze setting ð PAR1
Restorage of default setting in the
selected parameter set
2
Lenze setting ð PAR2
3
Lenze setting ð PAR3
4
Lenze setting ð PAR4
31
Lenze setting ð FPAR1
Restorage of default setting in the
fieldbus function module
61
Lenze setting ð PAR1 + FPAR1
Restorage of default setting in the
selected parameter set of the
controller and the fieldbus function
module
62
Lenze setting ð PAR2 + FPAR1
63
Lenze setting ð PAR3 + FPAR1
64
Lenze setting ð PAR4 + FPAR1
C0002*
uSEr
(cont.)
Parameter set
transfer using
the keypad
Use the keypad to transfer parameter
sets to other controllers.
During transfer the parameters
cannot be accessed via other
channels!
Keypad ð Controller
All available parameter sets (PAR1 ...
PAR4, and FPAR1) are overwritten with
the corresponding keypad data
70 With function module Application−I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
10 With all other function modules