2
Technical data
EDK82EV113 DE/EN/FR 8.1
L
92
General technical data
EMC Compliance with EN 61800−3/A11
Noise emission Compliance with limit value classes A and B to EN 55011
E82EVxxxKxC0xx without additional measures
E82EVxxxKxC2xx by means of external filters
Noise immunity
Requirements to EN 61800−3 incl. A11
Requirements Standard Severities
ESD EN 61000−4−2 3, i.e. 8 kV with air discharge,
6 kV with contact discharge
high frequency in cables EN 61000−4−6 150 kHz ... 80 MHz,
10 V/m 80 % AM (1kHz)
RF interference (enclosure) EN 61000−4−3 80 MHz ... 1000 MHz,
10 V/m 80 % AM (1kHz)
Burst EN 61000−4−4 3/4, i. e. 2 kV/5 kHz
Surge
(Surge on mains cable)
EN 61000−4−5 3, i.e. 1,2/50 s,
1 kV phase−phase,
2 kV phase−PE
Insulation resistance Overvoltage category III acc. to VDE 0110
Discharge current to PE (to EN
50178)
> 3.5 mA,
i. e. fixed installation and double PE connection are required.
Enclosure IP20
Protection measures against Short circuit, earth fault (earth−fault protected during operation, limited earth−fault protection
during power up), motor stalling, motor overtemperature (input for PTC or thermal contact, I
2
t
monitoring)
Insulation of control circuits Safe mains isolation: Double/reinforced insulation to EN 61800−5−1
permissible mains types
Operation at TT systems, TN systems or systems with grounded star point without additional
measures
Operation at IT systems is only possible with a variant
Permissible mains voltage
ranges
Frequency range
45 Hz − 0 % … 65 Hz + 0 %
DC power supply
1/N/PE AC 230/240 V
2/N/PE AC 230/240 V
180 V − 0 % ... 264 V + 0 % DC 140 V − 0 % ... 370 V + 0 %
3/PE AC 230/240 V 100 V − 0 % ... 264 V + 0 % DC 140 V − 0 % ... 370 V + 0 %
3/PE AC 400 V 320 V − 0 % ... 440 V + 0 % DC 450 V − 0 % ... 625 V + 0 %
3/PE AC 500 V 320 V − 0 % ... 550 V + 0 % DC 450 V − 0 % ... 775 V + 0 %
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com