Technical data
2
EDK82EV113 DE/EN/FR 8.1
93
L
Operation with rated power (normal operation)
Type
Power
Rated mains voltage
Mains current [A] Output current [A]
1)
Weight
[kW]
I
r
I
max
(60 s)
2)
[kg]
E82EV302K2C 3.0
3/PE AC 230/240 V
50 Hz
DC 325 V
15.6 12.0 12.0 18.0
2,9
E82EV402K2C 4.0 21.3 16.0 16.5 24.8
E82EV552K2C 5.5 29.3 21.0 22.5 33.8
3.6
E82EV752K2C 7.5 − 28.0 28.6 42.9
E82EV302K4C 3.0
3/PE AC 400 V
50 Hz
DC 565 V
9.0 7.0 7.3 11.0
2,9
E82EV402K4C 4.0 12,3 8.8 9,5 14.2
E82EV552K4C 5.5 16.8 12.0 13.0 19.5
E82EV752K4C 7.5 21.5 15.0 16.5 24.8
3.6
E82EV113K4C 11.0 − 21.0 23.5 35.3
E82EV302K4C 3.0
3/PE AC 500 V
50 Hz
DC 710 V
7.2 5.6 5.8 11.0
2,9
E82EV402K4C 4.0 9,8 7.0 7.6 14.2
E82EV552K4C 5.5 13.4 9.6 10.4 19.5
E82EV752K4C 7.5 17.2 12.0 13.2 24.8
3.6
E82EV113K4C 11.0 − 16.8 18.8 35.3
without mains choke
With mains choke
1)
With rated mains voltage and chopper frequency of 8 kHz
2)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
rx
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com