Operation with increased rated power
Under the application conditions described here the controller can be operated in
continuous operation with a motor of higher performance. The overload capacity is
reduced to 120 %.
Typical applications are pumps with square−law load characteristic or blowers.
) Note!
Operation with increased rated power is only permissible
l with the drive controllers mentioned
l within the mains voltage range mentioned
l with the chopper frequency mentioned
l with the prescribed fuses, cable cross−sections and mains chokes
Type
Power
Rated mains voltage
Mains current [A] Output current [A]
1)
[kW]
I
r
I
max
(60 s)
2)
E82EV302K2C 3.0
3/PE AC 230/240 V
50 Hz
DC 325 V
18.7 14.4 14.4 18.0
E82EV402K2C 4.0 Operation not possible
E82EV552K2C 5.5 25,7 27 33.8
E82EV752K2C 7.5 Operation not possible
E82EV302K4C 3.0
3/PE AC 400 V
50 Hz
DC 565 V
10.8 8.4 8.7 11.0
E82EV402K4C 4.0 10.6 11.4 14.2
E82EV552K4C 5.5 Operation not possible
E82EV752K4C 7.5 18.0 19.8 24.8
E82EV113K4C 11.0 Operation not possible
without mains choke
With mains choke
1)
For rated mains voltage and chopper frequency 2 kHz or 4 kHz
2)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
rx