Parameter reference
Parameters relevant for AS-i communication
65
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13214
C13220
Parameter | Name:
C13214 | CTT2 block parameter transfer: Read parameter block configuration
Data type: INTEGER_32
Index: 11361 = 0x2C61
CTT2 block parameter transfer Read mode ( 48)
Setting range (min. value | unit | max. value)
0.000 16000.000
Subcodes Lenze setting Info
C13214/1 50.000 ReadParamBlock:Index_1
C13214/2 51.000 ReadParamBlock:Index_2
C13214/3 53.000 ReadParamBlock:Index_3
C13214/4 54.000 ReadParamBlock:Index_4
C13214/5 58.000 ReadParamBlock:Index_5
C13214/6 61.000 ReadParamBlock:Index_6
C13214/7 64.001 ReadParamBlock:Index_7
C13214/8 98.000 ReadParamBlock:Index_8
C13214/9 133.000 ReadParamBlock:Index_9
C13214/10 137.000 ReadParamBlock:Index_10
C13214/11 150.000 ReadParamBlock:Index_11
C13214/12 155.000 ReadParamBlock:Index_12
C13214/13 158.000 ReadParamBlock:Index_13
C13214/14 443.001 ReadParamBlock:Index_14
C13214/15 444.001 ReadParamBlock:Index_15
C13214/16 179.000 ReadParamBlock:Index_16
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Scaling factor: 1000
Parameter | Name:
C13220 | Display: Last data to master
Data type: UNSIGNED_16
Index: 11355 = 0x2C5B
Display of the last data transmitted from the communication unit to the master.
Value is bit-coded:
Bit 0 D0
Bit 1 D1
Bit 2 D2
Bit 3 D3
Bit 4 PR0
Bit 5 PR1
Bit 6 PR2
Bit 7 PR3
Bit 8 Reserved
... ...
Bit 15 Reserved
Subcodes Info
C13220/1 Last data to master from slave 1
C13220/2 Last data to master from slave 2
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT