Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013 66
Parameter reference
Parameters relevant for AS-i communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13221
C13852
C13853
Parameter | Name:
C13221 | Display: Last data from master
Data type: UNSIGNED_16
Index: 11354 = 0x2C5A
Display of the last data transmitted from the master to the communication unit.
Value is bit-coded:
Bit 0 D0
Bit 1 D1
Bit 2 D2
Bit 3 D3
Bit 4 PR0
Bit 5 PR1
Bit 6 PR2
Bit 7 PR3
Bit 8 Reserved
... ...
Bit 15 Reserved
Subcodes Info
C13221/1 Last data from master to slave 1
C13221/2 Last data from master to slave 2
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13852 | All words to standard device
Data type: UNSIGNED_16
Index: 10723 = 0x29E3
Display of process data words 1 ... 8 which are transmitted from the communication unit to the drive unit.
Subcodes 1 ... 8 display all the process data words from the communication unit.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13852/1 Word 1 of process data from module to standard device
... ...
C13852/8 Word 8 of process data from module to standard device
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13853 | All words from standard device
Data type: UNSIGNED_16
Index: 10722 = 0x29E2
Display of process data words 1 ... 8 which are transmitted from the drive unit to the communication unit.
Subcodes 1 ... 8 display all the process data words from the drive unit.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13853/1 Word 1 process data from standard device to module
... ...
C13853/8 Word 8 of process data from standard device to module
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT