2 Features of the technology application
2.8 Pre-assignment of the I/O terminals
12
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.8 Pre-assignment of the I/O terminals
Terminal Function
Digital input terminals
X5/RFR Controller enable
X5/DI1
X5/DI2
Connection of positive/negative limit switches for monitoring of the travel range limits
• The connection is configured in a fail-safe fashion (LOW = limit switch activated).
DI1 Function
LOW Positive limit switch approached (activated)
HIGH Positive limit switch not approached (not activated)
DI2 Function
LOW Negative limit switch approached (activated)
HIGH Negative limit switch not approached (not activated)
Note!
If no limit switches are available:
1.Keep terminals DI1 and DI2 unconfigured.
2.Deactivate the inversion of DI1 and DI2: set bit 0 and bit 1 to "0" in C00114.
X5/DI3 Start positioning program
DI3 Function
LOWHIGH Start positioning program
Tip!
The "USER" LED status display on the front of the inverter is lit when the positioning program is
running.
X5/DI4 Reference switch connection
DI4 Function
LOW Reference switch activated
HIGH Reference switch not activated
X5/DI5
X5/DI6
Manual jog
DI5 DI6 Function
LOW LOW -
HIGH LOW Manual jog in positive direction
LOW HIGH Manual jog in negative direction
HIGH HIGH - / Manual jog in the direction selected first
X5/DI7 Reset error message and positioning program
DI7 Function
LOW No reset
LOWHIGH Reset error message
HIGH Reset positioning program
Analog input terminals
X3/A1U - (not assigned, can be used freely)
X3/A2U - (not assigned, can be used freely)