5 Appendix: Action types for the positioning sequence control
5.5 Switch
50
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.5 Switch
For switching digital output signals, 16 actions of the "Switch" type are provided. Each action can set
two bits of the wDigitalOutputs output signal, which can be selected, to "0" or "1", alternatively and
independently of each other.
Parameter Possible settings Info
Output switch. A
(C01411/1...16)
0Deactivated Selection of the sequencer output
which is to be set to the set polarity
by this action.
1 Sequencer output 1
(Bit 0 of wDigitalOutputs)
2 Sequencer output 2
(Bit 1 of wDigitalOutputs)
... ...
16 Sequencer output 16
(Bit 15 of wDigitalOutputs)
Pol. switch. A
(C01412/1...16)
Set output bit to "0" State to which the sequencer output
is to be set.
Set output bit to "1"
Output switch. B
(C01413/1...16)
0Deactivated Selection of the sequencer output
which is to be set to the set polarity
by this action.
1 Sequencer output 1
(Bit 0 of wDigitalOutputs)
2 Sequencer output 2
(Bit 1 of wDigitalOutputs)
... ...
16 Sequencer output 16
(Bit 15 of wDigitalOutputs)
Pol. switch. B
(C01414/1...16)
Set output bit to "0" State to which the sequencer output
is to be set.
Set output bit to "1"