5 Appendix: Action types for the positioning sequence control
5.9 Standby
54
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.9 Standby
For temporary activation of a speed or position follower, 5 actions of the "Standby" type are
provided.
Parameter Possible settings Info
Input f. "End"
(C01449/1...5)
1 Sequencer input 1
(Bit 0 of wDigitalInputs)
The follower mode selected remains
enabled until the sequencer input
selected here has the polarity set.
2 Sequencer input 2
(Bit 1 of wDigitalInputs)
... ...
16 Sequencer input 16
(Bit 15 of wDigitalInputs)
Polarity of input
(C01450/1...5)
Condition is bit state "0" State which the sequencer input
selected must have so that "Standby"
is exited and the sequence step is
processed.
Condition is bit state "1"
Follower mode
(C01451/1...5)
0 Speed follower Selection of the follower that is to be
activated in standby mode.
1 Position follower
Setpoint
(C01452/1...5)
-200 % 200 Setpoint for the speed follower
(displayed at nSet_a output).
Initialisation: 0.15 %
Detailed information relating to the basic drive functions "Speed follower" and "Position
follower" as well as to the corresponding parameters can be found in the reference
manual/online help of the inverter in the "Basic drive functions (MCK)" chapter.