4 Detailed functions of the technology application
4.2 Basic drive functions (MCK)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.2 Manual jog
In this operating mode, the drive can be traversed manually in a clockwise or anticlockwise direction
("jogging mode").
The basic function "Manual jog" is activated via bit 12 and bit 13 of the application control word
(L_ConvBitsToWord_2 FB). In the default setting, bit 12 and bit 13 are linked to digital inputs DI5
and DI6.
An activation via the fieldbus interface (MCI) is possible after a corresponding adaptation of the
user interface. See commissioning; Step 2 (optional): Establish control via the fieldbus interface
(MCI). ( 16)
C01222 MCK: Ref. M limit mode 14/15 10.00 %
C01223 MCK: Ref. waiting time mode 14/15 100 ms
C01227/1 MCK: Ref. offset reference degree 20.0000 unit
C01227/2 MCK: Ref. home position 0.0000 unit
C01228 MCK: Ref. sequence profile 0
C01229/1 MCK: Positive SW limit position 0.0000 units
C01229/2 MCK: Negative SW limit position 0.0000 units
C01246/1 MCK: Ref. TP signal source 0: No TP
Parameter Info Lenze setting
Value Unit
Note!
Additional logic operations in the application prevent the basic function "Manual jog"
from being activated if the positioning program is processed.
In the Lenze setting, the software limit positions parameterised are active for manual jog
if the home position is known. Limit position monitoring
( 39)