4 Detailed functions of the technology application
4.2 Basic drive functions (MCK)
32
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to go to the parameterisation dialog of the basic "Homing" function:
1. Open the parameter list for the LS_MotionControlKernel SB.
2. In the Block Parameters List... dialog box on the Application parameters tab, select the
"Homing" entry in the upper list field.
Note!
For a reference search with touch probe detection:
If the reference signal is to follow a real touch probe, the touch probe interface must be
configured accordingly via the Setting up TouchProbe... button!
Parameter Info Lenze setting
Value Unit
C01221 MCK: Homing mode 100: SetRef
C01224/1 MCK: Ref. initial speed 180.0000 unit/s
C01225/1 MCK: Ref. initial acceleration 3600.0000 unit/s2
C01224/2 MCK: Ref. search speed 60.0000 unit/s
C01225/2 MCK: Ref. search acceleration 3600.0000 unit/s2
C01226/1 MCK: Ref. S-ramp time 0.000 s