3 Short setup of the technology application
3.4 Step 3: Set commissioning parameters
22
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Following error monitoring system
C01215/1
(LS_MotionControl
Kernel)
0.0001 units 214748.3647 Limit for following error monitoring 1
The setting "0" deactivates following error
monitoring 1
Lenze setting: 500 units
C01215/2
(LS_MotionControl
Kernel)
0.0001 units 214748.3647 Limit for following error monitoring 2
The setting "0" deactivates following error
monitoring 2
Lenze setting: 1000 units
C00595/5...6
(LS_SetError_1)
Response at the activation of following error
monitoring
Subcode 5: response at the activation of following
error monitoring 1.
Subcode 6: response at the activation of following
error monitoring 2.
0No Reaction
1Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6Information
Limit position monitoring
C01229/1...2
(LS_MotionControl
Kernel)
-214748.3647 units 214748.3647 Positive and negative software limit position for
limiting the valid traversing range
Note:
The software limit positions are only evaluated if
the home position is known to the drive, and
the software limit positions for the respective
operating mode have been activated, and
the positive software limit position is set to a
greater value than the negative software limit
position!
Lenze setting: 0.0000 units
Parameter
(Block)
Possible settings
(Lenze setting printed in bold)
Info