3 Short setup of the technology application
3.4 Step 3: Set commissioning parameters
22
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Following error monitoring system
C01215/1
(LS_MotionControl
Kernel)
0.0001 units 214748.3647 Limit for following error monitoring 1
• The setting "0" deactivates following error
monitoring 1
Lenze setting: 500 units
C01215/2
(LS_MotionControl
Kernel)
0.0001 units 214748.3647 Limit for following error monitoring 2
• The setting "0" deactivates following error
monitoring 2
Lenze setting: 1000 units
C00595/5...6
(LS_SetError_1)
Response at the activation of following error
monitoring
• Subcode 5: response at the activation of following
error monitoring 1.
• Subcode 6: response at the activation of following
error monitoring 2.
0No Reaction
1Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6Information
Limit position monitoring
C01229/1...2
(LS_MotionControl
Kernel)
-214748.3647 units 214748.3647 Positive and negative software limit position for
limiting the valid traversing range
Note:
The software limit positions are only evaluated if
• the home position is known to the drive, and
• the software limit positions for the respective
operating mode have been activated, and
• the positive software limit position is set to a
greater value than the negative software limit
position!
Lenze setting: 0.0000 units
Parameter
(Block)
Possible settings
(Lenze setting printed in bold)
Info