3 Short setup of the technology application
3.5 Step 4: create the positioning program (sequence table)
24
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
General procedure
Proceed as follows to define the desired program flow:
1. Select the program step ((1 ... 100) that is to be edited in the Sequence table on the left.
2. Select the action type for the program step selected by clicking it in the Selection of action type
area.
If more than one action is provided for the action type selected, the next free action in the
Selection of action number list field is automatically proposed.
3. Optionally enter a comment on the action.
4. Set the action parameters.
Depending on the action type, further parameterisation dialogs can be called via buttons.
5. Repeat steps 1 ... 4 until all actions required for the program flow have been parameterised.
6. Click Close to change back to the function block editor.
A detailed description of the action types can be found in the Appendix. ( 42)
The L_Sequencer_1 FB is described in detail in the reference manual/online help for the
inverter in the "Function library »function blocks" chapter.