5 Appendix: Action types for the positioning sequence control
5.2 Positioning
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
S-ramp time (C01305/1...15)
Due to stipulation of an S-ramp time for a profile, the profile is executed with S-shaped ramps, i.e.
acceleration and braking processes are initiated smoothly in order to reduce jerk and thus the stress on
the drive components.
The acceleration/deceleration stipulated in the profile is not achieved until after the specified S-
ramp time.
This kind of acceleration/deceleration is needed for sensitive machine parts with a certain amount
of play.
The unavoidable consequence of the slower increase in acceleration in the case of the S profile is that
the positioning time is longer compared to the L profile, which is more efficient in terms of time.
Without jerk limitation (L profile)
With jerk limitation (S profile)
Final speed (C01305/1...15)
This specifies the speed at which the drive is to start the next profile after reaching the target position.
With a final speed not equal to "0", "velocity changeover" or "overchange" is possible, i.e. when the
target position is reached, a second positioning process is started immediately without the drive coming
to a standstill at the first target position.
Target position
Final speed (in this case, not equal to "0")
Sequence profile (C01307/1...15) for profile linkage/subsequent block control
A special feature is the automatic advancing to sequence profiles with and without velocity changeover.
For this purpose, the profile number of the desired sequence profile (1 15) is simply set in the
"Sequence profile" profile parameter.
After execution of the profile (target position reached), the set following (subsequent) profile is started
automatically. In this way, profile chains can be stipulated without additional control processes.
If the "Final speed" profile parameter is set to <> "0", a velocity changeover to the sequence profile
takes place at the final speed set.
If "0" is set for the following (i.e. subsequent) profile, profile linkage does not take place.
This function can be performed in all positioning modes.
TP profile (C01308/1...15)
Profile number of the profile (1 15) that is to be executed after a touch probe has been detected.
If "0" is set, there will be no profile stepping through touch probe.
Only relevant for positioning modes with touch-probe.
TP signal source (C01309/1...15)
Selection of the signal source for touch probe detection.
Only relevant for positioning modes with touch-probe.
Icon Profile parameter
E
a
v [unit/s]
t [s]
t [s]
F
v
pos
v
end
v [unit/s]
t [s]