Configuration
Code table
8
8.5
8.5−70
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1357 DIS: REF −2000000000 {1 inc} 2000000000 Function block INT1
l Display of the signal linked in
C13554
See System
Manual
(extension)
C1358 DIS: IN −32767 {1 rpm} 32767 Function block INT1
l Display of the signal linked in
C1355
C1359 DIS: RESET 0 1 Function block INT1
l Display of the signal linked in
C1356
C1360 INT2 function 0
Function selection, function
block INT2
See System
Manual
(extension)
0 PHI >= REF If INT2−IN ³ INT2−REF,
INT2−DOUT is set to HIGH
1 |PHI| >= |REF| If |INT2−IN| ³ |INT2−REF|,
INT2−DOUT is set to HIGH
C1361 INT2 scaling 6553600 65536 {1} 1000000000
Scaling factor, function block
INT2
INT2 * AOUT[%] +
INT2 * IN[inc]
C1361
@ 100
C1364
CFG: REF 1000 FIXED0INC Selection list 3 Input signal configuration
l Reference value
See System
Manual
(extension)
C1365
CFG: IN 1000 FIXEDPHI−0 Selection list 4 Configuration of input signal,
function block INT2
l Angle of rotation
C1366
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block INT2
l HIGH = Sets the integrator to
0
C1367 DIS: REF −2000000000 {1 inc} 2000000000 Function block INT2
l Display of the signal linked in
C13564
See System
Manual
(extension)
C1368 DIS: IN −32767 {1 rpm} 32767 Function block INT2
l Display of the signal linked in
C1365
C1369 DIS: RESET 0 1 Function block INT2
l Display of the signal linked in
C1366
C1370 FOLL max 100.00 0.00 {0.01 %} 199.99 Upper limit, function block
FOLL1
l Upper limit of the ramp
function generator
See System
Manual
(extension)
C1371 FOLL min −100.00 −199.99 {0.01 %} 0.00 Lower limit, function block
FOLL1
l Lower limit of the ramp
function generator
C1372 FOLL Tir 10.0 0.1 {0.1 s} 6000.0
Acceleration time T
ir
and
deceleration time T
if
of the ramp
function generator, function
block FOLL1
C1373 FOLL Tif 10.0 0.1 {0.1 s} 6000.0