Configuration
Code table
8
8.5
8.5−71
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1375
Selection list 1 Configuration of analog input
signals, function block FOLL1
See System
Manual
(extension)
1 CFG: SIGN 1000 FIXED0% l Negative value: signal
characteristic at FOLL1−OUT
is opposed to the one at
FOLL1−IN
l Positive value: signal
characteristic at FOLL1−OUT
is the same as at FOLL1−IN
2 CFG: IN 1000 FIXED0% If FOLL1−IN > FOLL1−REF, the
ramp function generator starts
3 CFG: REF 1000 FIXED0% Reference value
4 CFG: LOAD 1000 FIXED0% Initial value for the ramp
function generator
C1376
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FOLL1
l HIGH: initial value at
FOLL1−LOAD is accepted
C1377 −199.99 {0.01 %} 199.99
Function block FOLL1
l Display of the signals linked
in C1375
See System
Manual
(extension)
1 DIS: SIGN
2 DIS: IN
3 DIS: REF
4 DIS: LOAD
C1378 DIS: SET 0 1 Function block FOLL1
l Display of the signal linked in
C1376
C1583 fset high 100.00 0.00 {0.01 %} 199.99 Alterations by Lenze service
only!
Adaptation of the motor
magnetising current set in
C0095 (with V/f characteristic
control: influence limit of the
boost correction; with vector
control: influence limit of the
field precontrol)
l The output frequency is set
up to which the motor
magnetising current set in
C0095 is to have an effect.
l C1583 = 100 % ¢ half the
rated motor frequency in
C0089
6.11−5
C1751
0 {1} 65535
Inverter compensation
characteristic (WRK)
l During the motor parameter
identification, the
characteristic is calculated
from the measured motor
stator resistance and saved in
C1751/1 ... C1751/17
6.6−16
1 0
... ...
17 0
C1753
0 Data are not o. k.
Internal data are o. k.
l Motor data identification for
the inverter compensation
characteristic has been
completed successfully
1 Data are o. k.
efesotomasyon.com - Lenze