EtherNet/IP: Internal error [0x00c86100]
EtherNet/IP: Internal error [0x00c86101]
EtherNet/IP: Invalid parameter set [0x00c8641f]
EtherNet/IP: Lenze setting loaded [0x00c86420]
EtherNet/IP: Internal mapping error [0x00c86430]
EtherNet/IP: Invalid IP parameters [0x00c86533]
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication module is defective. Send communication module with error description to
Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication module is defective. Send communication module with error description to
Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
No active parameter set could be loaded. • Download application again (including module).
• Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to parameter set in memory module via standard
device was not successful.
• Download application again (including module).
• Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The entered I/O data mapping is invalid.
• An object not supporting the required properties has
been specified.
• More than 64 bytes of data have been mapped.
Repeat I/O configuration in the »Engineer«
( 55).
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
One or more IP parameters are faulty. Check and correct IP configuration.
Setting the IP configuration of the Servo Drive 9400
( 37)