EasyManuals Logo

Lenze Global Drive 9300 Servo PLC Series User Manual

Lenze Global Drive 9300 Servo PLC Series
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
9300 Servo PLC
System blocks
2.12 MCTRL_MotorControl
2-40
L
ServoPLC EN 2.0
2.12 MCTRL_MotorControl
Internal motor control (module number 131)
This SB contains the control function for the drive machine. It consists of: phase-angle controller,
speed controller and motor control.
C0907/3
C0042
MCTRL_nHiMLim_a
MCTRL_bQspOut_b
MCTRL_nLoMLim_a
MCTRL_bNMSwt_b
MCTRL_nNAdapt_a
MCTRL_bILoad_b
MCTRL_nISet_a
C0105
MCTRL_nNSet_a
100%
MCTRL_nPAdapt_a
C0254
MCTRL_dnPosSet_p
1
0
1
0
C0909
C0070
C0071
C0070
C0072
1
0
1
0
VECT_CTRL
PWM
C0050
MCTRL_bQspIn_b
MCTRL_nNSetIn_a
MCTRL_bMMax_b
C0056
MCTRL_nMSetIn_a
MCTRL_bIMax_b
MCTRL_nIAct_a
MCTRL_nDCVolt_a
MCTRL_nMAct_a
C0006
C0091
C0090
C0089
C0088
C0087
C0085
C0084
C0081
C0078
C0077
C0076
C0075
C0022
C0018
C0086
MCTRL_nPosLim_a
MCTRL_bPosOn_b
MCTRL_nNStartmLim_a
MCTRL_nMAdd_a
MCTRL_nFldWeak_a
UG-VOLTAGE
MONIT-LU
MCTRL_bUnderVoltage_b
C0053
C0173
MONIT-OU
MCTRL_bOverVoltage_b
MONIT-OC1
MCTRL_bShortCircuit_b
const
Imotor
C0022
const
MONIT-OC2
MCTRL_bEarthFault_b
>1,50I
NX
MONIT-OC5
MCTRL_bIxtOverload_b
const
MCTRL_nPos_a
MCTRL_nNAct_a
X7
Resolver
X8
Encoder
C0420
C0495
C0490 C0025
C0051
C0011 C0497
C0596
MCTRL_dnPos_p
MCTRL_bNmaxFault_b
MCTRL_nNmaxC11
MONIT-NMAX
MCTRL_nNAct_v
const
MONIT-Sd2
MCTRL_bResolverFault_b
OR
const
MONIT-Sd6
MCTRL_bEncoderFault_b
const
MONIT-Sd7
MCTRL_bSensorFault_b
0
1
2
3
4
C0490
E4
1
0
C0912 C0911
TP/MP
-Ctrl
C0910
MCTRL_bActTPReceived_b
MCTRL_dnActIncLastScan_p
150°C
MCTRL_bMotorTempGreaterSetValue_b
MONIT-OH3
C0063
Mot temp (X7 or X8)
C0121
MCTRL_bMotorTempGreaterC0121_b
MONIT-OH7
DIN44081
Terminal (T1/T2)
MCTRL_bPtcOverTemp_b
MONIT-OH8
85°C
MCTRL_bKuehlGreaterSetValue_b
MONIT-OH
C0061
Heatsink temp
C0122
MCTRL_bKuehlGreaterC0122_b
MONIT-OH4
C0906/4
C0906/3
C0907/2
C0907/4
C0906/8
C0906/5
C0907/1
C0906/6
C0906/2
C0906/7
C0906/1
C0906/9
C0908
+
-
MCTRL_MotorControl
0
1
Fig. 2-23 MCTRL_MotorControl
The process image is created in a fixed system task (interval: 1 msec).
Exception:
MCTRL_bActTPReceived_b
,
MCTRL_dnActIncLastScan_p
and
MCTRL_nNAct_v
are read into the process input image of the task in which they are actually used.
efesotomasyon.com - Lenze
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze Global Drive 9300 Servo PLC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze Global Drive 9300 Servo PLC Series and is the answer not in the manual?

Lenze Global Drive 9300 Servo PLC Series Specifications

General IconGeneral
BrandLenze
ModelGlobal Drive 9300 Servo PLC Series
CategoryDC Drives
LanguageEnglish

Related product manuals