9300 Servo PLC
System blocks
2.2 AIF2_IO_AutomationInterface
2-9
L
ServoPLC EN 2.0
2.2.2 Outputs_AIF2
Automation interface (module number 42)
This SB is used as interface for output signals (e.g. setpoint/actual value) from attached fieldbus
modules (e. g. INTERBUS, PROFIBUS-DP).
• Theprocessimageis
– created every 10 ms.
– created in an interval task within the time set for this task.
– read at the beginning of the task and written at its end.
Tip!
Please observe the corresponding Operating Instructions for the fieldbus module that is plugged in.
Outputs_AIF2
Automation
Interface
...
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
...
16 Bit
LowWord
16 Bit
HighWord
16 Bit
16 binary
signals
16 Bit
16 binary
signals
AIF2_nOutW2_a
AIF2_nOutW1_a
AIF2_bFDO0_b
AIF2_bFDO15_b
AIF2_bFDO16_b
AIF2_bFDO31_b
16 Bit
16 Bit
AIF2_nOutW4_a
AIF2_dnOutD1_p
AIF2_nOutW3_a
Fig. 2-4 Outputs_AIF2
Variable name
Data type Signal type Address DIS DIS format Note
AIF2_nOutW1_a %QW42.0
AIF2_nOutW2_a
%QW42.1
AIF2_nOutW3_a
In
eger analog
%QW42.2
AIF2_nOutW4_a %QW42.3
AIF2_bFDO0_b %QX42.0.0
... ...
AIF2_bFDO15_b
%QX42.0.15
AIF2_bFDO16_b
Bool binary
%QX42.1.0
... ...
AIF2_bFDO31_b %QX42.1.15
AIF2_dnOutD1_p Double-integer position %QD42.0